SitaMulti
Conventional outlet
- Products
-
SitaMulti
-
Conventional outlet
Size DN | External diameter OD (mm) | Opening/Core borehole (mm) | a (mm) |
---|---|---|---|
100 | 110 | 250 | 280 |
125 | 135 | 250 | 286 |
150 | 160 | 250 | 343 |
80 | 83 | 250 | 277 |
Performance text
Streamflow
Installation Examples
MultiCAD und BIM-Daten
Downloads
Article selection
SitaMulti roof outlet, vertical, made of cast iron, material EN-GJL-200, to DIN EN 1253-2, in sizes DN 80, DN 100, DN 125 and DN 150. For direct connection to SML pipes, for conventional drainage, with internal lugs to support the grating frame, with drilled holes to secure the roof outlet in the substructure, with weepholes, two sealing sleeves, six inserted stainless steel M12 threaded rods, washers, brass hexagon nuts and caps, with loose-fixed flange for clamping bitumen, plastic or EPDM roofing membranes, complete including dome grate, supply and install to professional standards.
Discharge rate according to DIN EN 1253-2 in l/s
Back-up Heigh (mm)
Discharge rate according to DIN EN 1253-2 with retaining element for emergency drainage in l/s
80
0.5
1.4
2.2
3.3
4.4
5.6
6.7
8
9.3
10.7
12
13.4
14.7
100
0.8
1.8
2.7
4.1
5.4
6.6
7.7
8.9
10.1
11.3
12.5
13.9
15.2
125
0.5
1.4
2.2
3.3
4.4
5.6
6.8
7.9
9
10.4
11.8
13.2
14.5
150
0.5
1.1
1.7
2.8
3.9
5.1
6.2
7.5
8.7
10.2
11.6
13.1
14.6
Back-up Heigh (mm)
80
0.5
1.6
2.6
4
5.4
7.1
8.7
10.6
12.5
14.7
16.8
17.6
18.4
100
0.9
2.2
3.4
4.9
6.4
8.1
9.8
12.1
14.3
16.9
19.4
23.3
27.2
125
1
2.3
3.5
5
6.4
8.3
10.2
12.4
14.5
17.1
19.7
25.9
32.1
150
0.6
1.9
3.2
4.6
5.9
7.7
9.5
11.6
13.7
16.5
19.3
26.4
33.4
SitaMulti in a ventilated roof structure
1 SitaMore reinforcement plate
2 SitaMulti insulating body for extension unit
SitaMulti extension unit consisting of:
3.1 Screw-on flange, nuts, washers and sealing sleeves
3.2 Sealing ring
3.3 Base body
SitaMulti consisting of:
4.1 Base body
4.2 Dome grate
4.3 Screw-on flange, nuts, washers and sealing sleeves
5 SitaMulti insulating body for outlet
6 SitaMulti insulating body for compensating ring
2 SitaMulti insulating body for extension unit
SitaMulti extension unit consisting of:
3.1 Screw-on flange, nuts, washers and sealing sleeves
3.2 Sealing ring
3.3 Base body
SitaMulti consisting of:
4.1 Base body
4.2 Dome grate
4.3 Screw-on flange, nuts, washers and sealing sleeves
5 SitaMulti insulating body for outlet
6 SitaMulti insulating body for compensating ring
Non-ventilated roof structure to the general rules of engineering with:
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaMulti with SitaMulti grating frame in a non-ventilated roof structure
1 SitaMulti insulating body for extension unit
SitaMulti grating frame consisting of:
2.1 Support ring
2.2 Grating frame with bolted end grate
3 SitaMulti Height compensation piece
SitaMulti extension unit consisting of:
4.1 Base body
4.2 Screw-on flange, nuts, washers and sealing sleeves
4.3 Sealing ring
SitaMulti consisting of:
5.1 Screw-on flange, nuts, washers and sealing sleeves
5.2 Base body
6 SitaMulti insulating body for compensating ring Ausgleichsring
7 SitaMulti insulating body for outlet
SitaMulti grating frame consisting of:
2.1 Support ring
2.2 Grating frame with bolted end grate
3 SitaMulti Height compensation piece
SitaMulti extension unit consisting of:
4.1 Base body
4.2 Screw-on flange, nuts, washers and sealing sleeves
4.3 Sealing ring
SitaMulti consisting of:
5.1 Screw-on flange, nuts, washers and sealing sleeves
5.2 Base body
6 SitaMulti insulating body for compensating ring Ausgleichsring
7 SitaMulti insulating body for outlet
Non-ventilated roof structure with slab paving on support pads to the general rules of engineering with:
- Slab paving
- Support pads
- Protective mat
- Sealing
- Thermal insulation
- Sloping screed
- Vapour barrier
- Substructure
SitaMulti with SitaMore retaining element for emergency drainage in a non-ventilated roof structure
1 SitaMulti insulating body for extension unit
SitaMulti extension unit consisting of:
2.1 Screw-on flange, nuts, washers and sealing sleeves
2.2 Sealing ring
2.3 Base body
SitaMore retaining element consisting of:
3.1 Base body
3.2 Sealing ring
3.3 Closed cover
3.4 Height-adjustable rubber-metal buffer
SitaMulti consisting of:
4.1 Screw-on flange, nuts, washers and sealing sleeves
4.2 Base body
5 SitaMulti insulating body for compensating ring
6 SitaMulti insulating body for outlet
SitaMulti extension unit consisting of:
2.1 Screw-on flange, nuts, washers and sealing sleeves
2.2 Sealing ring
2.3 Base body
SitaMore retaining element consisting of:
3.1 Base body
3.2 Sealing ring
3.3 Closed cover
3.4 Height-adjustable rubber-metal buffer
SitaMulti consisting of:
4.1 Screw-on flange, nuts, washers and sealing sleeves
4.2 Base body
5 SitaMulti insulating body for compensating ring
6 SitaMulti insulating body for outlet
Non-ventilated roof structure to the general rules of engineering with:
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaMulti with SitaStandard extension unit in a non-ventilated roof structure
SitaMulti consisting of:
1.1 Screw-on flange, nuts, washers and sealing sleeves
1.2 Dome grate
1.3 Base body
SitaStandard extension unit consisting of:
2.1 Base body
2.2 Sealing ring
3 SitaMulti insulating body for outlet
4 SitaMulti insulating body for compensating ring
1.1 Screw-on flange, nuts, washers and sealing sleeves
1.2 Dome grate
1.3 Base body
SitaStandard extension unit consisting of:
2.1 Base body
2.2 Sealing ring
3 SitaMulti insulating body for outlet
4 SitaMulti insulating body for compensating ring
Non-ventilated roof structure to the general rules of engineering with:
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaMulti with SitaMulti height compensation piece and grating frame in parking deck that can be driven on
SitaMulti consisting of:
1.1 Base body
1.2 Screw-on flange, nuts, washers and sealing sleeves
2 SitaMulti height compensation piece
SitaMulti grating frame consisting of:
3.1 Support ring
3.2 Grating
3.3 End grate
1.1 Base body
1.2 Screw-on flange, nuts, washers and sealing sleeves
2 SitaMulti height compensation piece
SitaMulti grating frame consisting of:
3.1 Support ring
3.2 Grating
3.3 End grate
Non-ventilated roof structure to the general rules of engineering with:
- Concrete slabs
- Protective screed
- Protective mat
- Sealing
- Substructure
In order for the external content to be displayed at this location, you must accept the cookies of the category "Preferences".
You can adjust the cookie settings here.
You can adjust the cookie settings here.
SitaMulti | Article no. | ||
---|---|---|---|
Vertical |
|||
DN 80 | 400399 | Show product | |
DN 100 | 400499 | Show product | |
DN 125 | 400699 | Show product | |
DN 150 | 400899 | Show product |
+