SitaStandard
Conventional outlet
- Products
-
SitaStandard
-
Conventional outlet
Size DN | External diameter OD (mm) | Opening/Core borehole (mm) | a (mm) |
---|---|---|---|
100 | 110 | 250 | 67 |
125 | 125 | 250 | 70 |
150 | 160 | 250 | 77 |
200 | 200 | 250 | 101 |
70 | 75 | 250 | 65 |
SitaStandard vertical, made of polyurethane, thermally insulated, to DIN EN 1253-2, in sizes DN 70, DN 100, DN 125, DN 150 and DN 200. For direct connection to pipes with plug-in coupler, for conventional drainage, with large foamed-in connection sleeve of choice (495 mm x 495 mm) to suit the roofing membrane and with fixing ring for additional securing of the connection sleeve and to hold the supplied dome grate, with foamed-in heating element to EN 60335-1/2 for DN 70 to DN 150, DN 200 with pipe sleeve heating, and 2.0 m cable for connecting direct to 230 V with a heat rating of approx. 10 W, supply and install to professional standards.
SitaStandard vertical, in a non-ventilated roof structure
SitaStandard vertical consisting of:
2.1 Base body
2.2 Dome grate
SitaStandard extension unit consisting of:
3.1 Base body
3.2 Sealing ring
4 SitaStandard insulating body for extension unit
5 SitaMore reinforcement plate
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaStandard with retaining element and downpipe in a non-ventilated roof structure
1.1 Height-adjustable rubber-metal buffers
1.2 Closed cover
1.3 Sealing ring
1.4 Base body
SitaStandard extension unit consisting of:
2.1 Base body
2.2 Sealing ring
3 SitaStandard insulating body for extension unit
4 SitaStandard insulating body for outlet
5 SitaStandard vertical
6 SitaMore reinforcement plate
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaStandard main drainage in a non-ventilated roof structure with greenery
2 SitaStandard vertical
SitaStandard extension unit consisting of:
3.1 Sealing ring
3.2 Base body
SitaGreen green roof shaft consisting of:
4.1 Inspection grate
4.2 Base body
4.3 Height-adjustable rubber-metal buffers
5 SitaStandard insulating body for extension unit
- roof greenery according to system provider
- drainage mat
- building protection mat
- Sealing
- Heat insulation
- Vapour barrier
- Substructure
SitaStandard vertical with SitaGreen green roof shaft for main drainage in an inverted roof
2 SitaStandard vertical
3 SitaStandard extension unit without sealing ring
SitaGreen green roof shaft consisting of:
4.1 Inspection grate
4.2 Base body
4.3 Height-adjustable rubber-metal buffers
- Roof greenery according to system supplier
- Filter fabric
- Drainage mat
- Protective mat
- XPS thermal insulation
- Waterproof membrane
- Substructure
You can adjust the cookie settings here.