SitaTrendy
Conventional outlet
- Products
-
SitaTrendy
-
Conventional outlet
Size DN | External diameter OD (mm) | Opening/Core borehole (mm) | a (mm) | b (mm) |
---|---|---|---|---|
100 | 110 | 250 | 75 | 210 |
125 | 125 | 250 | 79 | 210 |
70 | 75 | 250 | 63 | 210 |
Performance text
Streamflow
Installation Examples
MultiCAD und BIM-Daten
Downloads
Article selection
SitaTrendy vertical, made of polyurethane, thermally insulated, to DIN EN 1253-2, in sizes DN 70, DN 90, DN 100 and DN 125. For direct connection to pipes with plug-in coupler, for conventional drainage, with large connection sleeve of choice (495 mm x 495 mm) to suit the roofing membrane and with fixing ring for additional securing of the connection sleeve and to hold the supplied dome grate, with foamed-in heating element to EN 60335-1/2 and 2.0 m cable for connecting direct to 230 V with a heat rating of approx. 10 W, supply and install to professional standards.
Discharge rate according to DIN EN 1253-2 in l/s
Back-up Heigh (mm)
Discharge rate according to DIN EN 1253-2 with retaining element for emergency drainage in l/s
70
0.6
1.4
2.2
3.1
3.9
4.7
5.5
6.6
7.6
8.6
9.5
10.4
11.3
100
0.6
1.5
2.3
3.3
4.3
5.2
6.1
7.3
8.5
9.4
10.3
11
11.7
125
0.7
1.6
2.4
3.3
4.2
5.1
5.9
7.3
8.7
10.1
11.4
12.7
14
Back-up Heigh (mm)
70
1.2
2.1
2.9
4.4
5.8
7.3
8.8
10.5
12.1
12.4
12.6
13.1
13.5
100
1.2
2.3
3.3
4.7
6.1
7.8
9.4
11.4
13.3
15.2
17
19.6
22.2
125
1.2
2.2
3.2
4.6
6
7.5
9
10.7
12.4
14.3
16.2
18.5
20.8
SitaTrendy screw-on flange in a non-ventilated roof structure with terrace slabs in a gravel bed
1 SitaTrendy insulating body for extension unit
SitaTrendy extension unit consisting of:
2.1 Sealing ring
2.2 Base body
SitaMore terrace kit consisting of:
3.1 End grate
3.2 Housing
3.3 Height adjustment ring
SitaTrendy screw-on flange vertical consisting of:
4.1 Base body
4.2 Loose flange, seals and screws
5 SitaTrendy insulating body for outlet
SitaTrendy extension unit consisting of:
2.1 Sealing ring
2.2 Base body
SitaMore terrace kit consisting of:
3.1 End grate
3.2 Housing
3.3 Height adjustment ring
SitaTrendy screw-on flange vertical consisting of:
4.1 Base body
4.2 Loose flange, seals and screws
5 SitaTrendy insulating body for outlet
Non-ventilated roof structure with slab paving in gravel bed to the general rules of engineering with:
- Slab paving
- Grit or gravel bed
- Drainage mat
- Protective mat
- Sealing
- Thermal insulation
- Vapour barrier
- Substructure
SitaTrendy and SitaDrain® Terra for the main drainage of slab paving on gravel bed without thermal insulation
1 SitaPipe Edelstahl pipe
2 SitaTrendy insulating body for outlet
3 SitaTrendy vertical
4 SitaDrain gravel strip
SitaDrain® Terra consisting of:
3.1 Inspection grate
3.2 Frame
3.3 Height-adjustable rubber-metal buffers
2 SitaTrendy insulating body for outlet
3 SitaTrendy vertical
4 SitaDrain gravel strip
SitaDrain® Terra consisting of:
3.1 Inspection grate
3.2 Frame
3.3 Height-adjustable rubber-metal buffers
Ventilated roof structure with slab paving in gravel bed to the general rules of engineering with:
- Slab paving
- Grit or gravel bed
- Drainage mat
- Protective mat
- Waterproof membrane
- Substructure
SitaTrendy retaining element for emergency drainage as a waterspout in a ventilated roof structure
SitaMore retaining element consisting of:
1.1 Height-adjustable rubber-metal buffers
1.2 Closed cover
1.3 Sealing ring
1.4 Base body
SitaTrendy extension unit consisting of:
2.1 Base body
2.2 Sealing ring
3 SitaTrendy insulating body for extension unit
4 SitaTrendy vertical
5 SitaPipe Edelstahl safety clamp
6 SitaPipe Edelstahl bend
7 SitaPipe Edelstahl pipe clamp
8 SitaPipe Edelstahl pipe
9 SitaAttika cladding cover plate
1.1 Height-adjustable rubber-metal buffers
1.2 Closed cover
1.3 Sealing ring
1.4 Base body
SitaTrendy extension unit consisting of:
2.1 Base body
2.2 Sealing ring
3 SitaTrendy insulating body for extension unit
4 SitaTrendy vertical
5 SitaPipe Edelstahl safety clamp
6 SitaPipe Edelstahl bend
7 SitaPipe Edelstahl pipe clamp
8 SitaPipe Edelstahl pipe
9 SitaAttika cladding cover plate
Non-ventilated roof structure to the general rules of engineering with:
- Sealing
- Thermal insulation
- Vapour barrier
- Substructure
- Parapet lead-through with joint tape
SitaTrendy with retaining element for emergency drainage in a non-ventilated roof structure with extensive greenery
1 SitaTrendy insulating body for outlet
2 SitaTrendy vertical
SitaTrendy extension unit consisting of:
3.1 Sealing ring
3.2 Base body
SitaMore retaining element consisting of:
4.1 Base body
4.2 Sealing ring
4.3 Height-adjustable rubber-metal buffers
4.4 Closed cover
2 SitaTrendy vertical
SitaTrendy extension unit consisting of:
3.1 Sealing ring
3.2 Base body
SitaMore retaining element consisting of:
4.1 Base body
4.2 Sealing ring
4.3 Height-adjustable rubber-metal buffers
4.4 Closed cover
Non-ventilated roof structure with extensive greenery to the general rules of engineering with:
- Extensive roof greenery with vegetation layer according to system supplier
- Protection, drain and filter layer according to system supplier
- Sealing
- Thermal insulation
- Vapour barrier
- Substructure
In order for the external content to be displayed at this location, you must accept the cookies of the category "Preferences".
You can adjust the cookie settings here.
You can adjust the cookie settings here.
+