Size DN | External diameter OD (mm) | Opening/Core borehole (mm) | a (mm) |
---|---|---|---|
100 | 110 | 250 | 67 |
125 | 125 | 250 | 70 |
150 | 160 | 250 | 77 |
200 | 200 | 250 | 101 |
70 | 75 | 250 | 65 |
Performance text
Streamflow
Installation Examples
MultiCAD und BIM-Daten
Downloads
Article selection
SitaStandard vertical, made of polyurethane, thermally insulated, to DIN EN 1253-2, in sizes DN 70, DN 100, DN 125, DN 150 and DN 200. For direct connection to pipes with plug-in coupler, for conventional drainage, with large foamed-in connection sleeve of choice (495 mm x 495 mm) to suit the roofing membrane and with fixing ring for additional securing of the connection sleeve and to hold the supplied dome grate, supply and install to professional standards.
Discharge rate according to DIN EN 1253-2 in l/s
Back-up Heigh (mm)
Discharge rate according to DIN EN 1253-2 with retaining element for emergency drainage in l/s
70
0.7
1.7
2.7
3.8
4.8
6
7.1
8.3
9.4
10.8
12.2
13.5
14.8
100
0.7
1.8
2.8
3.8
4.8
6.1
7.4
8.5
9.6
11
12.3
13.6
14.8
125
0.7
1.8
2.9
4.1
5.2
6.4
7.6
8.7
9.7
11
12.3
14.1
15.8
150
0.6
1.6
2.6
3.6
4.6
5.9
7.2
8.2
9.2
11
12.8
14
15.1
200
0.5
1.5
2.5
3.5
4.5
5.8
7.1
8.1
9.2
10.6
12
13.3
14.5
Back-up Heigh (mm)
70
1.2
2.2
3.1
4.6
6
7.6
9.2
11.1
13
13.9
14.8
14.9
14.9
100
1.6
2.8
4
5.5
7
8.8
10.5
12.3
14.1
16.7
19.3
22.8
26.2
125
1.2
2.3
3.4
4.9
6.3
7.9
9.5
11.6
13.6
16.1
18.6
21.9
25.2
150
1.4
2.4
3.4
4.9
6.3
8
9.6
11.6
13.6
16.2
18.7
22.3
25.8
SitaStandard vertical, in a non-ventilated roof structure
1 SitaStandard insulating body for outlet
SitaStandard vertical consisting of:
2.1 Base body
2.2 Dome grate
SitaStandard extension unit consisting of:
3.1 Base body
3.2 Sealing ring
4 SitaStandard insulating body for extension unit
5 SitaMore reinforcement plate
SitaStandard vertical consisting of:
2.1 Base body
2.2 Dome grate
SitaStandard extension unit consisting of:
3.1 Base body
3.2 Sealing ring
4 SitaStandard insulating body for extension unit
5 SitaMore reinforcement plate
Non-ventilated roof structure to the general rules of engineering with:
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaStandard with retaining element and downpipe in a non-ventilated roof structure
SitaMore retaining element consisting of:
1.1 Height-adjustable rubber-metal buffers
1.2 Closed cover
1.3 Sealing ring
1.4 Base body
SitaStandard extension unit consisting of:
2.1 Base body
2.2 Sealing ring
1.1 Height-adjustable rubber-metal buffers
1.2 Closed cover
1.3 Sealing ring
1.4 Base body
SitaStandard extension unit consisting of:
2.1 Base body
2.2 Sealing ring
3 SitaStandard insulating body for extension unit
4 SitaStandard insulating body for outlet
5 SitaStandard vertical
6 SitaMore reinforcement plate
Non-ventilated roof structure to the general rules of engineering with:
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaStandard main drainage in a non-ventilated roof structure with greenery
1 SitaStandard insulating body
2 SitaStandard vertical
SitaStandard extension unit consisting of:
3.1 Sealing ring
3.2 Base body
SitaGreen green roof shaft consisting of:
4.1 Inspection grate
4.2 Base body
4.3 Height-adjustable rubber-metal buffers
5 SitaStandard insulating body for extension unit
2 SitaStandard vertical
SitaStandard extension unit consisting of:
3.1 Sealing ring
3.2 Base body
SitaGreen green roof shaft consisting of:
4.1 Inspection grate
4.2 Base body
4.3 Height-adjustable rubber-metal buffers
5 SitaStandard insulating body for extension unit
Non-ventilated roof structure with greenery according to the general rules of engineering with:
- roof greenery according to system provider
- drainage mat
- building protection mat
- Sealing
- Heat insulation
- Vapour barrier
- Substructure
SitaStandard vertical with SitaGreen green roof shaft for main drainage in an inverted roof
1 SitaStandard insulating body
2 SitaStandard vertical
3 SitaStandard extension unit without sealing ring
SitaGreen green roof shaft consisting of:
4.1 Inspection grate
4.2 Base body
4.3 Height-adjustable rubber-metal buffers
2 SitaStandard vertical
3 SitaStandard extension unit without sealing ring
SitaGreen green roof shaft consisting of:
4.1 Inspection grate
4.2 Base body
4.3 Height-adjustable rubber-metal buffers
Inverted roof structure to the general rules of engineering with:
- Roof greenery according to system supplier
- Filter fabric
- Drainage mat
- Protective mat
- XPS thermal insulation
- Waterproof membrane
- Substructure
In order for the external content to be displayed at this location, you must accept the cookies of the category "Preferences".
You can adjust the cookie settings here.
You can adjust the cookie settings here.
+