SitaFireguard®
Fire protection outlet
| Size DN | External diameter OD (mm) | Opening/Core borehole (mm) | Recess dimension (mm x mm) | a (mm) | Bridging of thermal insulation min. (mm) | Bridging of thermal insulation max. (mm) |
|---|---|---|---|---|---|---|
| 150 | 160 | 300 | 300 x 300 | 550 | 105 | 570 |
| 150 | 160 | 300 | 300 x 300 | 200 | 65 | 210 |
| 100 | 110 | 235 | 190 x 190 | 200 | 65 | 210 |
| 100 | 110 | 235 | 190 x 190 | 550 | 105 | 570 |
| 125 | 125 | 255 | 200 x 200 | 200 | 65 | 210 |
| 125 | 125 | 255 | 200 x 200 | 550 | 105 | 570 |
| 70 | 75 | 185 | 150 x 150 | 200 | 65 | 210 |
| 70 | 75 | 185 | 150 x 150 | 550 | 105 | 570 |
SitaFireguard® with retaining element for preventive fire protection and to prevent the spread of fire from below where there are small penetrations according to DIN 18234 Part 3 and 4, in two parts, consisting of: PE base body with collar for fixing to the reinforcement plate and for clamping the vapour barrier, to DIN EN 1253-2. Including extension unit for insulating material thicknesses from 65 mm to 210 mm or 105 mm to 570 mm made of PUR with large connection sleeve of choice and signal yellow retaining element. For direct connection to pipes with plug-in coupler, for conventional drainage, with a sealing sleeve and a reinforcement plate to DIN EN 1090-4, with pre-assembled fire protection sleeve, supply complete and install to professional standards.
|
Back-up Heigh (mm) | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Size DN | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 | 100 |
| 70 | 0.9 | 2.3 | 3.4 | 4.8 | 6 | 7.2 | 8.7 | 10.3 | 11.6 | 12.4 | 12.9 | 13.5 | 14 | 16.2 | 16.5 | 16.5 | 16.5 | 16.5 | 16.5 | 16.5 |
| 100 | 1 | 2.2 | 3.3 | 4.5 | 5.7 | 7.1 | 8.6 | 10 | 11.5 | 13.4 | 15.4 | 17.4 | 20 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| 125 | 1 | 2.2 | 3.3 | 4.6 | 6 | 7.4 | 8.9 | 10.5 | 12 | 13.5 | 15.4 | 18 | 22 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| 150 | 0.8 | 1.5 | 2 | 4.6 | 6 | 7.4 | 8.7 | 10 | 11.4 | 13.1 | 15 | 16.6 | 18 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
SitaFireguard emergency drainage in a non-ventilated roof structure
1 Reinforcement plate
2 Sealing sleeve
3 Self-tapping screw
4 Seal
5 Fire protection sleeve
6 PE base body
7 Extension unit
8 Retaining element base body
9 Retaining element sealing ring
10 Retaining element cover
11 Height-adjustable rubber-metal buffers
- Sealing
- Thermal insulation non-flammable, min. 1.0 m x 1.0 m
- Vapour barrier
- Non-flammable section fillers
- Steel trapezoidal section
You can adjust the cookie settings here.
Technical drawings
PDF TechnischeZeichnung_F302900_en.pdfPDF TechnischeZeichnung_F303000_en.pdf
PDF TechnischeZeichnung_F303300_en.pdf
PDF TechnischeZeichnung_F303400_en.pdf
PDF TechnischeZeichnung_F303700_en.pdf
PDF TechnischeZeichnung_F303800_en.pdf
PDF TechnischeZeichnung_F304100_en.pdf
PDF TechnischeZeichnung_F304200_en.pdf
DWG TZ_DB_SitaFireguard_NE_DN100_200_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN100_550_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN125_200_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN125_550_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN150_200_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN150_550_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN70_200_Manschette.DWG
DWG TZ_DB_SitaFireguard_NE_DN70_550_Manschette.DWG