SitaIndra
Parapet outlet
Size DN | External diameter OD (mm) | a (mm) |
---|---|---|
70 | 75 | 520 |
70 | 75 | 1020 |
70 | 75 | 1520 |
SitaIndra parapet outlet, angled, made of polyurethane, thermally insulated, according to DIN EN 1253-2, in size DN 70, discharge rate 5.8 l/s at 35 mm retaining height, with stainless steel connection pipe and safety clamp, vapour barrier plate flex for secure connection to the vapour barrier and two-part insulating body made of polyurethane with a thermal conductivity lambda=0.0249 W/mK and a compressive strength of 200 kPa, size: 500 x 1000 x 120 mm. For conventional drainage, with large foamed-in connection sleeve of choice (495 x 495 mm) to suit the roofing membrane and with fixing ring for additional securing of the connection sleeve and to hold the supplied dome grate, supply and install to professional standards.
Back-up Heigh (mm) | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Support length | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 | 100 |
1.0 metres | 0.6 | 1.4 | 2.2 | 2.3 | 2.4 | 2.5 | 2.6 | 2.7 | 2.8 | 2.9 | 2.9 | 3 | 3.1 | 3.2 | 3.2 | 3.3 | 3.4 | 3.5 | 3.5 | 3.5 |
1.5 metres | 0.6 | 1.4 | 2.2 | 2.3 | 2.4 | 2.5 | 2.6 | 2.7 | 2.8 | 2.9 | 2.9 | 3 | 3.1 | 3.2 | 3.2 | 3.3 | 3.4 | 3.5 | 3.5 | 3.5 |
2.0 metres | 0.6 | 1.4 | 2.2 | 2.3 | 2.4 | 2.5 | 2.6 | 2.7 | 2.8 | 2.9 | 2.9 | 3 | 3.1 | 3.2 | 3.2 | 3.3 | 3.4 | 3.5 | 3.5 | 3.5 |
Back-up Heigh (mm) | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Support length | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 | 100 |
2.0 metres | 0.6 | 1.5 | 2.3 | 2.6 | 2.9 | 4.4 | 5.8 | 7 | 8.2 | 9.5 | 10.8 | 11.5 | 12.2 | 12.6 | 12.9 | 13.8 | 14.7 | 14.7 | 14.7 | 14.7 |
1.5 metres | 0.6 | 1.5 | 2.3 | 2.6 | 2.9 | 4.4 | 5.8 | 7 | 8.2 | 9.5 | 10.8 | 11.5 | 12.2 | 12.6 | 12.9 | 13.8 | 14.7 | 14.7 | 14.7 | 14.7 |
1.0 metres | 0.6 | 1.5 | 2.3 | 2.6 | 2.9 | 4.4 | 5.8 | 7 | 8.2 | 9.5 | 10.8 | 11.5 | 12.2 | 12.6 | 12.9 | 13.8 | 14.7 | 14.7 | 14.7 | 14.7 |
SitaIndra main drainage set in a non-ventilated roof structure
2 SitaPipe Edelstahl pipe clamp
3 SitaPipe Edelstahl safety clamp
4 SitaPipe Edelstahl bend 87.5°
5 SitaAttika cladding cover plate
SitaIndra main drainage set consisting of:
6.1 Vapour barrier plate flex
6.2 Insulating body
6.3 Pipe
6.4 Safety clamp
6.5 Base body
6.6 Dome grate base body
6.7 Dome grate cover
7 SitaPipe Edelstahl cleaning pipe
8 SitaPipe Edelstahl transition piece eccentric
- Sealing
- Thermal insulation
- Vapour barrier
- Substructure
- Parapet lead-through with joint tape
SitaIndra for main drainage in a non-ventilated roof structure with internal downspout
2 SitaPipe Edelstahl pipe
3 SitaPipe Edelstahl safety clamp
4 SitaPipe Edelstahl bend 87.5°
SitaIndra main drainage set consisting of:
5.1 SitaMore vapour barrier plate flex
5.2 SitaPipe Edelstahl pipe
5.3 SitaPipe Edelstahl safety clamp
5.4 SitaIndra dome grate
5.5 SitaIndra base body
5.6 SitaIndra insulating body
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
SitaIndra and SitaKaskade Inside for main drainage in a non-ventilated roof structure
2 SitaPipe Edelstahl safety clamp
3 SitaMore sealing sleeve for WDVS
4 SitaPipe Edelstahl pipe
SitaIndra main drainage set consisting of:
5.1 Vapour barrier plate flex
5.2 Insulating body
5.3 Pipe
5.4 Safety clamp
5.5 Base body with connection sleeve of choice
5.6 Dome grate base body
5.7 Dome grate cover
SitaKaskade Inside for downpipe consisting of:
6.1 Loose flange with sealing sleeves, nuts, washers and protective caps
6.2 Cascade component with threaded rods
6.3 Safety clamp
6.4 Bend 15°
6.5 Bend 30°
6.6 Vapour barrier plate
6.7 Bend 87.5°
- Waterproof membrane
- Thermal insulation
- Vapour barrier
- Substructure
You can adjust the cookie settings here.
Installation Examples
PDF SitaIndra_Hauptentwaesserungsset_im_nicht_beluefteten_Dachaufbau.pdfPDF SitaIndra_fuer_die_Hauptentwaesserung_im_nicht_beluefteten_Dachaufbau_mit_innenliegendem_Fallrohr.pdf
PDF SitaIndra_und_SitaKaskade_Inside_fuer_die_Hauptentwaesserung_im_nicht_beluefteten_Dachaufbau.pdf
Technical drawings
PDF TechnischeZeichnung_107300_en.pdfPDF TechnischeZeichnung_107310_en.pdf
PDF TechnischeZeichnung_10731500_en.pdf
PDF TechnischeZeichnung_10731510_en.pdf
PDF TechnischeZeichnung_10732000_en.pdf
PDF TechnischeZeichnung_10732010_en.pdf
DWG TZ_DB_SitaIndra_Hauptentwaesserung_PUR_1000.DWG
DWG TZ_DB_SitaIndra_Hauptentwaesserung_PUR_1500.dwg
DWG TZ_DB_SitaIndra_Hauptentwaesserung_PUR_2000.dwg